Ding HeRequest a quoteQuote

Radiant Barrier R Value: What It Means for Foil Insulation

A radiant barrier r value is often requested as if foil had one fixed number. The useful answer starts with what R-value measures, how foil insulation assemblies are documented, and which laminate builds Ding He supplies for insulation facing and duct wrap.

Ask about reflective foil materials

Reflective insulation under a warehouse roof (application)

Radiant Barrier R Value: What It Means for Foil Insulation

A radiant barrier r value is not a single fixed number for a bare foil. A radiant barrier is a reflective, low-emissivity surface facing an air space, not a bulk insulator. R-value measures resistance to conductive heat flow, while radiant barriers reduce only radiant heat transfer; there is no current method for assigning an R-value to radiant barriers. A standalone foil number cannot therefore be compared directly with the R-value of a batt, board or complete foil insulation assembly. The distinction matters when a specification mixes a component label with an assembly target.

Installed performance depends on the full assembly. A study reports polished aluminum films can exhibit emissivity values as low as 0.05–0.07, supporting their use as radiant barriers to minimize radiative heat transfer. The useful comparison is between complete constructions: what faces the air space, what core is present, and how the layers are fixed. A bare foil figure does not describe those conditions, and the same foil grade can sit in very different builds.

Comparisons become clearer when the claimed number is tied to a drawing and a set of assumptions. A building-science resource states a radiant barrier system can reduce attic heat flow by approximately 40%, corresponding to 8% to 12% of annual cooling costs. That result belongs to the studied system, not to a foil roll on its own. Buyers should use system-level data, the air-space assumptions and the orientation behind the claim, then compare like with like.

Ding He supplies foil laminates as components for insulation facing and duct wrap. The company operates coating and lamination lines at its factory in Lin’an, Zhejiang. Foil and film are slit on automatic high-speed CNC machines. For a build-specific feasibility review, send the laminate structure, thickness, width and quantity. Ding He replies to inquiries within 1 working day. The company updated its production line and machinery in 2020.

Foil Insulation R Value: How to Read the Number

‘R foil insulation’ is not a standalone rated product in the same way as a batt. The R refers to the thermal resistance of the installed assembly, while the foil surface affects radiant heat transfer. The same foil can be part of assemblies with different R-values, so compare assembly drawings, air spaces and the data behind the claim rather than a material label. Ding He can review laminate build feasibility for a proposed facing or duct wrap; the installed R-value is not a Ding He laminate property.

Ding He’s role is to supply the laminate to an agreed structure, not to assign an installed R-value. The company can review a proposed build and discuss the carrier, foil layer and any heat-seal layer named in the request. Final performance belongs to the assembly, with its air spaces and fixing details. A trial quantity can be discussed for a new project before a larger order. For a new project, send the proposed structure and the intended use so the laminate discussion starts from the assembly.

Foil Laminate Builds for Insulation Facing and Duct Wrap

Ding He makes ultra-thin aluminum laminate materials for industrial rolls. Ding He states that its coating and lamination lines have an annual capacity of around 10,000 tons. Processes include dry lamination, solvent-free lamination, extrusion coating lamination, coating and slitting. Foil and film are slit on fully automatic, high-speed CNC slitting machines of German origin. Products used in insulation facing and duct wrap include AL/PET laminate film, AL/Kraft paper laminate film, AL/fiberglass fabric laminate film and AL/non-woven fabric laminate film. Each is supplied as a component; the finished assembly determines thermal performance.

For reflective insulation facing, the foil surface is paired with a carrier such as kraft paper or fiberglass fabric, and the product may face an air space in the completed build. For duct wrap, the laminate is supplied on reel for fabricators who combine it with other materials. FSK facing is one example within the kraft-paper family. An analysis supporting a radiant barrier fact sheet states that quantifying benefits is complex because they depend on climate, attic geometry, duct arrangements, and other building parameters. That is why a laminate datasheet should be read as a component description, not as an installed R-value.

Product selection starts with the build. AL/PET laminate film combines the metallic barrier of aluminum foil with the strength and flexibility of polyester. AL/Kraft paper laminate film is an aluminum foil face laminated to kraft paper for insulation facing and vapor retarders. AL/fiberglass fabric laminate film is for roofing and insulation. AL/non-woven fabric laminate film integrates the barrier properties of aluminum foil with the lightweight, breathable and flexible performance of non-woven fabric. Ding He can review which laminate suits a requested structure. The request can name the carrier, foil layer and any heat-seal layer.

Ding He supplies customers in 20+ countries, with main markets in South America, Southeast Asia and Eastern Asia, and it also exports to Europe, America and Japan. Export customers are mainly HVAC duct producers, insulation makers and cable shielders. Trial quantities are possible for new projects, and the minimum order depends on the build. Lead time differs by product and order quantity and is confirmed for each order. Third-party inspection by agencies such as BV or SGS is accepted. Payment is by T/T, L/C, D/P, D/A, Western Union, MoneyGram and PayPal, and shipping is from Shanghai port, Ningbo port or another port the customer prefers.

Radiant barrier R-value questions

What is the R-value of foil bubble wrap insulation?

There is no single R-value that applies to all foil bubble wrap. The foil facing is a reflective surface, while the bubble core and adjacent air spaces belong to the product assembly. Ask for the value tied to the exact product build and installation, including the air-space assumptions. A bare foil number should not be used as if it were the whole assembly value.

Sources

Request a quotation

Tell us the application and the reflective laminate you are considering.

Or write to sales@foillaminates.com

* Required